  1.     SECTION 06152
  2.  
  3.     WOOD ROOF DECKING
  4. NOTE ** This section is based on the products of the Homasote Company, which is located at:
  5. NOTE **    P.O. Box 7240
  6. NOTE **    West Trenton, NJ  08628-0240
  7. NOTE **    Tel:  (609) 883-3300
  8. NOTE **    Fax:  (609) 530-1584
  9. NOTE **    Internet address:  http://www.homasote.com
  10. NOTE **    For local rep contact:  Sweet's Buyline 1-800-892-1165 (#0878)
  11. NOTE ** 
  12. NOTE ** The Homasote Company manufactures various products for the building industry.  This section covers only a part of their product line:  "Firestall(R)" and "Easy-ply(R)" roof decking.  See their other sections for fiberboard underlayment, acoustical barriers (fire-rated and non-rated), and acoustical wall panels (fabric-covered and cork-faced).
  13. NOTE ** 
  14. NOTE ** SECTION 06152 - WOOD ROOF DECKING, Copyright 1998, The Architect's Catalog, Inc.
  15.  
  16. PART 1    GENERAL
  17.  
  18. 1.1    SECTION INCLUDES
  19.  
  20.     A.    Furnishing and installing factory fabricated and finished roof decking.
  21.  
  22. 1.2    RELATED SECTIONS
  23. NOTE ** Delete sections below not relevant to this project; add others as required.
  24.  
  25.     A.    Section 06100 - Rough Carpentry.
  26.  
  27.     B.    Section 07311 - Asphalt Shingles.
  28.  
  29.     C.    Section 07313 - Wood Shingles and Shakes.
  30.  
  31.     D.    Section 07322 - Clay Roofing Tile.
  32.  
  33.     E.    Section 07325 - Ceramic Slate Roofing.
  34.  
  35.     F.    Section _____ - _________________________.
  36.  
  37. 1.3    REFERENCES
  38. NOTE ** Delete references from the list below that are not actually required by the text of the edited section; add others as required.
  39.  
  40.     A.    ASTM E 84 - Test Method for Surface Burning Characteristics of Building Materials.
  41.  
  42.     B.    Factory Mutual Research Corporation (FMRC) Standard for Class A (25 Flame Spread) for rated decking.
  43.  
  44.     C.    UL R5268.
  45.  
  46.     D.    ________________________________________.
  47.  
  48. 1.4    SUBMITTALS
  49.  
  50.     A.    Submit under provisions of Section 01300.
  51.  
  52.     B.    Product Data:  Manufacturer's product and complete installation data for all materials in this specification.
  53.  
  54.     C.    Shop Drawings:  Prepared specifically for this project; show profiles, joining method, assembly details, adjacent construction interface, and dimensions.
  55.  
  56.     D.    Installation Guide:  Product manufacturer's written installation guide.
  57. NOTE ** Delete the following paragraph if samples are not required.
  58.  
  59.     E.    Samples:  Sized to adequately represent material.
  60.  
  61.     F.    Closeout Submittals:  Warranty and Manufacturer's performance certifications.
  62.  
  63. 1.5    QUALITY ASSURANCE
  64.  
  65.     A.    Roof decking manufacturer shall certify that fire retardant roof decking meets performance design criteria according to the following test standards:
  66. NOTE ** Select the following subparagraphs as applicable; delete others.
  67.         1.    ASTM E 84.
  68.         2.    FMRC Standard for Class A (25 Flame Spread) for rated decking.
  69.         3.    UL R5268.
  70.  
  71. 1.6    DELIVERY, STORAGE, AND HANDLING
  72.  
  73.     A.    Deliver materials in the manufacturer's original sealed, labeled packaging.
  74.  
  75.     B.    Store materials in a dry, well-vented area above ground on wooden pallets and covered.  
  76.  
  77.     C.    Inspect the materials upon delivery to assure that specified products have been received.
  78.  
  79.     D.    Report damaged material immediately to the delivering carrier and note such damage on the carrier's freight bill of lading.
  80.  
  81.     E.    Remove protective packaging immediately prior to installation.
  82.  
  83. 1.7    PROJECT CONDITIONS
  84.  
  85.     A.    Verify that other trades are complete before installing the roof decking.
  86.  
  87.     B.    Ensure that mounting surfaces are straight and secure and that substrates are of proper material per roofing deck manufacturer.
  88.  
  89.     C.    Refer to the construction documents, shop drawings, and manufacturer's installation instructions.
  90.  
  91.     D.    Coordinate installation with roof membrane manufacturer's installation instructions.  Decking installation must be followed immediately with finish roofing.
  92.  
  93.     E.    Observe all appropriate OSHA safety guidelines for this work.
  94. NOTE ** Delete the following article if no warranties are required, or if work is covered under the terms of a general project warranty specified elsewhere.  You may edit the article to obtain a warranty from the Contractor only, or to suit other project-specific criteria.
  95.  
  96. 1.8    WARRANTY
  97.  
  98.     A.    Manufacturer's Standard Warranty:  Materials shall be free of defects in material and workmanship for one year after shipment.
  99.  
  100.     B.    If, after inspection, the manufacturer agrees that materials are defective, the manufacturer shall, at their option, repair or replace them.
  101.  
  102.  
  103. PART 2    PRODUCTS
  104.  
  105. 2.1    MANUFACTURERS
  106.  
  107.     A.    Acceptable Manufacturer:  Homasote Company, P.O. Box 7240, West Trenton, NJ 08628-0240; ASD. Tel: (609) 883-3300, Fax: (609) 530-1584, Internet address:  http://www.homasote.com; For local rep contact:  Sweet's Buyline 1-800-892-1165 (#0878).
  108.  
  109.     B.    Requests for substitutions will be considered in accordance with provisions of Section 01600.  Proposed substitutions shall meet the performance and quality standards of this specification.
  110. NOTE ** Delete paragraph above or below; coordinate with Division 1 requirements.
  111.  
  112.     C.    Substitutions:   Not permitted.
  113.  
  114.     D.    Provide all wood roof decking from a single manufacturer.
  115.  
  116. 2.2    ROOF DECKING
  117. NOTE ** Select type of wood roof decking required for project from the two paragraphs below.  
  118. NOTE ** 
  119. NOTE ** Firestall(R) is a nailable UL Class "A" fire-rated structural roof decking with a face ply of Homasote NCFR(R).
  120. NOTE ** 
  121. NOTE ** Easy-ply(R) is a multiple-ply roof decking made of high density Homasote structural board with a surface of decorative white vinyl film which serves as both an interior finish and a vapor barrier.
  122.  
  123.     A.    Structural Roof Decking:  Firestall(R) Roof Decking, a composition of Homasote structural board and a face ply of UL Class A NCFR Homasote.
  124. NOTE ** Select panel thicknesses from the subparagraphs below; delete those not required for the project.
  125.         1.    Panel Thickness:  1 inch (25.4 mm).
  126.         2.    Panel Thickness:  1-3/8 inches (34.9 mm).
  127.         3.    Panel Thickness:  1-7/8 inches (47.6 mm).
  128.         4.    Panel Thickness:  2-3/8 inches (60.3 mm).
  129.         5.    Panel Size:  Nominal 24 by 96 inches (610 by 2438 mm), actual 23-1/8 by 95-7/8 inches (587 by 2435 mm).
  130.         6.    Flame Spread:  Class I or A.
  131.         7.    Noise Reduction Coefficient:  20.
  132. NOTE ** Coordinate R-value selection below with thickness selected above.
  133.         8.    Thermal R-Value:  2.05 for 1 inch (25.4 mm).
  134.         9.    Thermal R-Value:  2.5 for 1-3/8 inches (34.9 mm).
  135.         10.    Thermal R-Value:  3.1 for 1-7/8 inches (47.6 mm).
  136.         11.    Thermal R-Value:  4.9 for 2-3/8 inches (60.3 mm).
  137. NOTE ** Coordinate weight below with thickness selected above.  Delete those not required for the project.
  138.         12.    Weight:  2.62 psf (12.79 kg/sq. m) for 1 inch (25.4 mm).
  139.         13.    Weight:  3.48 psf (16.99 kg/sq. m) for 1-3/8 inches (34.9 mm).
  140.         14.    Weight:  4.63 psf (22.60 kg/sq. m) for 1-7/8 inches (47.6 mm).
  141.         15.    Weight:  5.78 psf (28.68 kg/sq. m) for 2-3/8 inches (60.3 mm).
  142. NOTE ** Coordinate rafter spacing below with thickness selected above or add rafter spacings required for the project.  Delete those not required for the project.  Ten psf (48.8 kg/sq. m) dead load is assumed.
  143.         16.    Maximum Rafter Spacing, 50 psf (244 kg/sq. m) Live Loads:  24 inches (610 mm) for 1 inch (25.4 mm).
  144.         17.    Maximum Rafter Spacing, 50 psf (244 kg/sq. m) Live Loads:  32 inches (812 mm) for 1-3/8 inches (34.9 mm).
  145.         18.    Maximum Rafter Spacing, 50 psf (244 kg/sq. m) Live Loads:  48 inches (1,219 mm) for 1-7/8 inches (47.6 mm).
  146.         19.    Maximum Rafter Spacing, 50 psf (244 kg/sq. m) Live Loads:  48 inches (1,219 mm) for 2-3/8 inches (60.3 mm).
  147.         20.    Maximum Rafter Spacing:  ________________________.
  148.  
  149.     B.    Structural Roof Decking:  Easy-ply(R) Roof Decking, a composition of Homasote structural board with a 6 mil pre-finished surface of a decorative white "flitter" vinyl film, Class "C" fire resistance rating per ASTM E 84.
  150. NOTE ** Select panel thicknesses from the subparagraphs below; delete those not required for the project.
  151.         1.    Panel Thickness:  1 inch (25.4 mm).
  152.         2.    Panel Thickness:  1-3/8 inches (34.9 mm).
  153.         3.    Panel Thickness:  1-7/8 inches (47.6 mm).
  154.         4.    Panel Thickness:  2-1/16 inches (52.4 mm).
  155.         5.    Panel Size:  Nominal 24 by 96 inches (610 by 2438 mm), actual 23-1/8 by 95-7/8 inches (587 by 2435 mm).
  156.         6.    Fire Resistance Rating:  Class C per ASTM E 84; 100 Flame Spread, 230 Smoke Developed.
  157. NOTE ** Coordinate R-value selection below with thickness selected above.
  158.         7.    Thermal R-Value:  2.4 for 1 inch (25.4 mm).
  159.         8.    Thermal R-Value:  3.27 for 1-3/8 inches (34.9 mm).
  160.         9.    Thermal R-Value:  4.46 for 1-7/8 inches (47.6 mm).
  161.         10.    Thermal R-Value:  5.0 for 2-1/16 inches (52.4 mm).
  162. NOTE ** Coordinate weight below with thickness selected above.
  163.         11.    Weight:  2.4 psf (11.72 kg/sq. m) for 1 inch (25.4 mm).
  164.         12.    Weight:  3 psf (14.65 kg/sq. m) for 1-3/8 inches (34.9 mm).
  165.         13.    Weight:  4 psf (19.53 kg/sq. m) for 1-7/8 inches (47.6 mm).
  166.         14.    Weight:  5 psf (24.41 kg/sq. m) for 2-1/16 inches (52.4 mm).
  167. NOTE ** Coordinate rafter spacing below with thickness selected above or add rafter spacings required for the project.  Delete those not required for the project.  Ten psf (48.8 kg/sq. m) dead load is assumed.
  168.         15.    Maximum Rafter Spacing, 40 psf (195 kg/sq. m) Live Loads:  24 inches (610 mm) for 1 inch (25.4 mm).
  169.         16.    Maximum Rafter Spacing, 40 psf (195 kg/sq. m) Live Loads:  32 inches (812 mm) for 1-3/8 inches (34.9 mm).
  170.         17.    Maximum Rafter Spacing, 40 psf (195 kg/sq. m) Live Loads:  48 inches (1,219 mm) for 1-7/8 inches (47.6 mm).
  171.         18.    Maximum Rafter Spacing, 40 psf (195 kg/sq. m) Live Loads:  48 inches (1,219 mm) for 2-1/16 inches (52.4 mm).
  172.         19.    Maximum Rafter Spacing, 50 psf (244 kg/sq. m) Live Loads:  16 inches (406 mm) for 1 inch (25.4 mm).
  173.         20.    Maximum Rafter Spacing, 50 psf (244 kg/sq. m) Live Loads:  24 inches (610 mm) for 1-3/8 inches (34.9 mm).
  174.         21.    Maximum Rafter Spacing, 50 psf (244 kg/sq. m) Live Loads:  32 inches (812 mm) for 1-7/8 inches (47.6 mm).
  175.         22.    Maximum Rafter Spacing, 50 psf (244 kg/sq. m) Live Loads:  48 inches (1,219 mm) for 2-1/16 inches (52.4 mm).
  176.         23.    Maximum Rafter Spacing, A-Frame:  32 inches (812 mm) for 1 inch (25.4 mm).
  177.         24.    Maximum Rafter Spacing, A-Frame:  48 inches (1,219 mm) for 1-3/8 inches (34.9 mm).
  178.         25.    Maximum Rafter Spacing, A-Frame:  48 inches (1,219 mm) for 1-7/8 inches (47.6 mm).
  179.         26.    Maximum Rafter Spacing, A-Frame:  48 inches (1,219 mm) for 2-1/16 inches (52.4 mm).
  180.         27.    Maximum Rafter Spacing:  ______________________.
  181.  
  182.  
  183. PART 3    EXECUTION
  184.  
  185. 3.1    EXAMINATION
  186.  
  187.     A.    Verify that the roof decking installation will not disrupt other trades.  
  188.  
  189.     B.    Verify that substrate is dry, clean, and free of foreign matter.
  190.  
  191.     C.    Report and correct defects prior to any installation.
  192.  
  193. 3.2    PREPARATION
  194.  
  195.     A.    Submit design drawings for review and approval before installation. 
  196.  
  197.     B.    Check as-built conditions and verify the manufacturer's roof decking details for accuracy to fit the roof configuration. 
  198.  
  199. 3.3    INSTALLATION
  200.  
  201.     A.    Comply with roof decking manufacturer's current installation guide.
  202.  
  203.     B.    Install roof decking in dry condition only.